<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Tempco Blog &#187; Cogenerazione</title>
	<atom:link href="http://www.tempcoblog.it/category/cogenerazione/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.tempcoblog.it</link>
	<description>Soluzioni per l'energia termica</description>
	<lastBuildDate>Fri, 03 Sep 2010 06:17:39 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.1</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>ORC Organic Rankine Cycle</title>
		<link>http://www.tempcoblog.it/2378/orc-organic-rankine-cycle/</link>
		<comments>http://www.tempcoblog.it/2378/orc-organic-rankine-cycle/#comments</comments>
		<pubDate>Wed, 23 Jun 2010 07:19:05 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[Torri Evaporative]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=2378</guid>
		<description><![CDATA[ORC acronimo di Organic Rankine Cycle, sembra essere il nuovo trend nella cogenerazione.
Partito qualche anno fa, su taglie di impianto consistenti, grazie allo sviluppo della tecnologia delle microturbine, si sta espandendo a macchia d&#8217;olio.



In sostanza si sfruttano le caratteristiche fisiche di fluidi organici particolari, utilizzando il calore esausto di cicli di lavorazione, per mettere in [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/2378/orc-organic-rankine-cycle/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Cogenerazione e teleriscaldamento</title>
		<link>http://www.tempcoblog.it/2302/cogenerazione-e-riscaldamento/</link>
		<comments>http://www.tempcoblog.it/2302/cogenerazione-e-riscaldamento/#comments</comments>
		<pubDate>Tue, 04 May 2010 08:20:17 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[dissipatori]]></category>
		<category><![CDATA[teleriscaldamento]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=2302</guid>
		<description><![CDATA[L&#8217;altro giorno ho visto una interessante applicazione dove abbiamo installato una serie di elettroradiatori.
Si tratta di un impianto di cogenerazione con motori endotermici a gas, per il riscaldamento e la produzione di energia per un centro sportivo nelle vicinanze di Milano.

Il centro sportivo comprende una piscina con annessa palestra.
L&#8217;impianto di cogenerazione, asserve il centro sportivo [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/2302/cogenerazione-e-riscaldamento/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Raffreddamento  e deumidificazione del biogas</title>
		<link>http://www.tempcoblog.it/2218/raffreddamento-e-deumidificazione-del-biogas/</link>
		<comments>http://www.tempcoblog.it/2218/raffreddamento-e-deumidificazione-del-biogas/#comments</comments>
		<pubDate>Fri, 26 Mar 2010 08:52:03 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[biogas]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=2218</guid>
		<description><![CDATA[Negli impianti di cogenerazione funzionanti con biogas, ho più volte parlato della necessità di trattare l&#8217;effluente all&#8217;uscita dal digestore.
Solitamente il biogas deriva da discariche, mangimifici, allevamenti animali, dove vengono sfruttati i gas prodotti dagli scarti, per produrre a loro volta energia.
Ci si ritrova spesso in ambiente atex per via della presenza del biogas stesso ovviamente.
Installare [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/2218/raffreddamento-e-deumidificazione-del-biogas/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Pulizia di un recuperatore per fumi</title>
		<link>http://www.tempcoblog.it/2079/pulizia-di-uno-recuperatore-per-fumi/</link>
		<comments>http://www.tempcoblog.it/2079/pulizia-di-uno-recuperatore-per-fumi/#comments</comments>
		<pubDate>Thu, 11 Feb 2010 09:52:54 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Manutenzione]]></category>
		<category><![CDATA[recupero energetico]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=2079</guid>
		<description><![CDATA[Negli impianti di cogenerazione si può recuperare una interessante quota di energia dai fumi di combustione.
Nel caso di impianti con motori endotermici la stessa cosa si può fare con i fumi esausti del motore.

Nel caso questi scambiatori si sporchino, ovviamente c&#8217;è un decadimento delle prestazioni e del recupero energetico.
Risulta quindi importante una facile manutenzione e [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/2079/pulizia-di-uno-recuperatore-per-fumi/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Biogas e corrosione</title>
		<link>http://www.tempcoblog.it/2000/biogas-e-corrosione/</link>
		<comments>http://www.tempcoblog.it/2000/biogas-e-corrosione/#comments</comments>
		<pubDate>Thu, 07 Jan 2010 16:02:13 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Condense]]></category>
		<category><![CDATA[Corrosione]]></category>
		<category><![CDATA[biogas]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=2000</guid>
		<description><![CDATA[Abbiamo ormai decine di applicazioni attive nel campo della cogenerazione tramite biogas.
Si tratta di una applicazione collaudata e standardizzata.
In questi ultimi anni, abbiamo anche avuto modo di analizzare e risolvere alcune delle più frequenti insidie che possono creare problemi a questa tipologia di impianti: la corrosione ambientale.

E&#8217; chiaro e risaputo che il biogas è un [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/2000/biogas-e-corrosione/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Elettroradiatori con ventilatori prementi o aspiranti</title>
		<link>http://www.tempcoblog.it/1875/elettroradiatori-con-ventilatori-prementi-o-aspiranti/</link>
		<comments>http://www.tempcoblog.it/1875/elettroradiatori-con-ventilatori-prementi-o-aspiranti/#comments</comments>
		<pubDate>Fri, 09 Oct 2009 15:03:05 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[aerorefrigeranti]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[elettroradiatori]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=1875</guid>
		<description><![CDATA[I radiatori normalmente installati sui gruppi di produzione di energia di emergenza conteinerizzati o meno, sono solitamente dotati di ventilatori assiali prementi. Tali radiatori sono montati verticalmente vicono al motore, in quanto la ventola solitamente è trascinata meccanicamente dal motore stesso.

Sempre più spesso, i gruppi elettrogeni di emergenza ed i gruppi di cogenerazione a motori [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/1875/elettroradiatori-con-ventilatori-prementi-o-aspiranti/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Cogenerazione e biogas</title>
		<link>http://www.tempcoblog.it/1527/cogenerazione-e-biogas/</link>
		<comments>http://www.tempcoblog.it/1527/cogenerazione-e-biogas/#comments</comments>
		<pubDate>Mon, 20 Jul 2009 08:28:13 +0000</pubDate>
		<dc:creator>S. Pellucchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Glossary]]></category>
		<category><![CDATA[biogas]]></category>
		<category><![CDATA[energia chimica]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=1527</guid>
		<description><![CDATA[Il biogas è una miscela gassosa combustibile composta principalmente da metano. Il biogas si ricava da materiale organico e con l&#8217;aiuto di microrganismi, di conseguenza esattamente come i residui che produce, rientra nel ciclo di vita naturale delle sostanze.


Come si forma il biogas
Le sostanze organiche (per esempio cereali, mais o effluenti zootecnici), vengono convogliate in [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/1527/cogenerazione-e-biogas/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Depurazione del biogas per gli impianti di cogenerazione</title>
		<link>http://www.tempcoblog.it/1516/depurazione-del-biogas-per-gli-impianti-di-cogenerazione/</link>
		<comments>http://www.tempcoblog.it/1516/depurazione-del-biogas-per-gli-impianti-di-cogenerazione/#comments</comments>
		<pubDate>Thu, 09 Jul 2009 13:36:19 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[biogas]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=1516</guid>
		<description><![CDATA[Prima dell’utilizzo a fini energetici negli impianti di cogenerazione il biogas deve essere sottoposto ad opportuna depurazione. Infatti la presenza di azoto, anidride carbonica ed acqua provoca l’abbassamento del potere colorifico della miscela gassosa, sostanze come l’idrogeno solforato ed i composti organici alogenati, che possono essere presenti nel biogas, si comportano da agenti corrosivi, causando danni [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/1516/depurazione-del-biogas-per-gli-impianti-di-cogenerazione/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Cogenerazione e raffreddatori evaporativi</title>
		<link>http://www.tempcoblog.it/1431/cogenerazione-e-raffreddatori-evaporativi/</link>
		<comments>http://www.tempcoblog.it/1431/cogenerazione-e-raffreddatori-evaporativi/#comments</comments>
		<pubDate>Thu, 11 Jun 2009 09:10:41 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Raffreddatori evaporativi]]></category>
		<category><![CDATA[Torri Evaporative]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=1431</guid>
		<description><![CDATA[Per un importante impianto di cogenerazione realizzato in Spagna, abbiamo fornito dei raffreddatori evaporativi a circuito chiuso.
L&#8217;utilizzo è dedicato al raffreddamento dell&#8217;acqua asservita ai condensatori.
Il cliente ha preferito la soluzione in circuito chiuso, in quanto non voleva inquinamenti o sporcamenti nelle tubazioni dei condensatori, parte delicata e strategica per la produzione di energia.
E&#8217; importante sapere [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/1431/cogenerazione-e-raffreddatori-evaporativi/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Scambiatori a piastre e teleriscaldamento</title>
		<link>http://www.tempcoblog.it/1212/scambiatori-a-piastre-e-teleriscaldamento/</link>
		<comments>http://www.tempcoblog.it/1212/scambiatori-a-piastre-e-teleriscaldamento/#comments</comments>
		<pubDate>Wed, 20 May 2009 15:32:31 +0000</pubDate>
		<dc:creator>Valter Biolchi</dc:creator>
				<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[recupero energetico]]></category>
		<category><![CDATA[teleriscaldamento]]></category>

		<guid isPermaLink="false">http://www.tempcoblog.it/?p=1212</guid>
		<description><![CDATA[Negli impianti di teleriscaldamento è generalizzato l&#8217;utilizzo degli scambiatori di calore a piastre.
Questo per diversi motivi:

dimensioni compatte
elevate capacità di scambio termico
resistenza meccanica
incrocio delle temperature

Gli scambiatori a piastre vengono utilizzati sia nelle centrali di produzione dell&#8217;energia o di cogenerazione, che nelle sottostazioni locali dove viene utilizzata l&#8217;energia prodotta.

Solitamente nelle centrali di produzione si utilizzano scambiatori a [...]]]></description>
		<wfw:commentRss>http://www.tempcoblog.it/1212/scambiatori-a-piastre-e-teleriscaldamento/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
